Know What Your Opening Will Take Before You Shop for Gas

Ask About Fireplace Inspection

What the Job Involves

This visit is about the box you would be converting. We record the opening's size, how deep the hearth runs out in front, and how far the wood mantel sits above. On factory-built units we find the maker's label, because it decides which gas products are allowed inside. You leave with a short list of logs or inserts that suit the space, plus anything that needs fixing before one goes in.

Opening size recorded for log and insert sizing
Hearth extension depth compared with what gas units ask
Mantel and side trim distances noted
Maker's label located on factory-built boxes
Short list of gas products that suit the opening

The Room Side of the Chimney, Checked for a Change of Fuel

This visit is about the opening you sit in front of, not the stack above it, and the question it answers is what that opening can hold. For owners leaning toward gas, that is the question that decides the shopping list. We look at the firebox walls and floor for cracks and loose firebrick, at the damper to see whether it opens fully and can be clamped, and at the hearth to see whether it is level and deep enough. Then we measure. Gas log sets are sold by the width and depth of the firebox, and inserts by the height and width of the opening plus the depth behind it, and a mismatch is the most common reason a set looks wrong or an insert will not slide in. We also look for a gas supply: many older fireplaces in Lawndale have a log lighter valve and a stub in the side wall, while others have no gas at all, which changes the price of any conversion.

Factory-built fireplaces need their own care. They are steel shells set into a framed wall, found in plenty of South Bay condos and newer houses, and each one carries a rating plate that says what it was tested with. Some accept a specific gas log kit from the same maker; many accept nothing but wood; very few accept a generic insert. We find the plate, note the model and tell you what that box allows, because putting the wrong gas appliance into a factory-built unit can overheat the casing and the framing around it. If the plate is missing or unreadable, we say so plainly, and the options narrow to the ones that are safe without it. The findings come to you in writing with the measurements, so you can take them to a showroom or hand them back to us.

Clearances, Mantels and the Hearth in Front

Heat does not stay in the firebox, and the fire code sets distances between the opening and anything that burns. A gas fire runs cooler than oak, but those distances still apply, and they apply again to the new surround or mantel many owners pick out alongside a conversion. During the visit we note how far the mantel shelf sits above the opening, how close any wood trim comes to the sides, and how far the hearth reaches into the room. A television mounted above the mantel gets a mention too, since an insert blowing warm air upward can cook electronics. When a measurement falls short, the written findings say which part needs to move or change and why. That turns into a remodel plan if you want one, or a short list of fixes if you would rather keep the room as it is.

Booking is simple. Use the contact page, tell us whether the fireplace is brick or metal, whether you have seen a gas key near it, and what you are hoping to burn. The visit is often paired with a sweep or a Level 1 chimney inspection at $54, so the flue and the opening are judged together, since a log set in a sound firebox still needs a clear path for its exhaust. Owners in Hawthorne and Inglewood with condos and townhomes should mention the building, because homeowner association rules sometimes limit what can go into a shared chimney, and we would rather know that before measuring. After the visit you have numbers, not guesses, and the next step is yours to choose. Some owners book the gas work straight away; others take the sheet to a showroom first, and both are fine with us.

How Mulligan Chimney Works Works

Chimney First

The flue and firebox are looked at before any gas unit is chosen

Options Compared

Logs, an insert or a direct-vent unit, set out one at a time

Prices on Paper

Each line of the job written down before work begins

Lit With You There

The new unit runs its first cycle while you watch the controls

Other Services

Chimney Sweep

Brushing and vacuuming a wood-burning flue so it is clean for the last fires of the season or ready for a gas conversion.

Open →

Chimney Inspection

An NFPA 211 look at the chimney you have now, written up so you know which gas option it can carry.

Open →

Chimney Repair

Masonry, flue and roofline fixes that have to happen before a gas appliance can vent safely through an older chimney.

Open →

Fireplace Repair

Cracked firebrick, a worn damper or a loose hearth put right, so the fireplace is ready to burn wood or to take gas.

Open →

Chimney Level 2 Inspection

Video of the flue from smoke chamber to cap, booked before an insert goes in, after a quake, or ahead of a sale.

Open →

Chimney Cap Installation

A metal top over the flue that stops rain and nesting birds, sized for wood flues and for liners serving gas inserts.

Open →

Chimney Flashing Repair

Resealing the metal where roof and chimney meet, so a gas conversion does not end with a stained ceiling beside it.

Open →

Chimney Masonry Repair

Repointing open joints and replacing crumbling brick on the outside of the stack, matched to the color already there.

Open →

Chimney Rebuilds

Taking down a cracked or leaning stack and building it again, sometimes shorter or lighter when the fireplace is going gas.

Open →

Fireplace Cleaning

Soot, ash and smoke marks cleared from the firebox and surround, often the first job before a conversion quote.

Open →

Gas Fireplace Cleaning

A yearly service for gas units: burner and pilot cleared, media set right, and the flame and vent looked at.

Open →

Gas Fireplace Repair

Finding why a gas fireplace refuses to light, keeps dropping the pilot or burns a weak flame, then fitting the failed part.

Open →

Fireplace Remodel

Rebuilding the fireplace wall around a new gas unit, with surround, mantel and hearth planned for its heat and size.

Open →

Fireplace Inserts

A sealed gas or wood heater fitted into the existing firebox, with a liner up the chimney and a face panel to finish.

Open →

Pellet Stove Repair

Finding the fault when a pellet stove stops feeding, will not ignite or shuts itself down, then fitting the right part.

Open →

Wood Stove Repair

New baffles, firebrick, door rope and glass for owners keeping wood a few more winters before any switch to gas.

Open →

Gas Logs

Ceramic logs on a gas burner set in your masonry fireplace, the simplest way to stop hauling wood and still see flames.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter rebuild for brick above the roof, so the stack is less likely to fall in a strong quake.

Open →

Chimney Crown Repair

Sealing or recasting the cement top of a masonry chimney so rain stops soaking down into the brick and flue.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct, from the machine to the outside hood, so loads dry faster and the run stays safer.

Open →

Chimney Liner Installation

A stainless liner run through an old clay flue, sized to the gas insert, log set or wood stove that will vent through it.

Open →

Chimney Leak Repair

Tracing the path rain takes into the chimney and closing it at the source, up on the roof.

Open →

Chimney Waterproofing

A repellent for brick that lets the wall dry out while turning away most of the winter rain.

Open →

Chimney Damper Repair

Repairing or replacing the metal flap inside the flue, which matters again when a vented gas log set goes in.

Open →

Chimney Chase Cover

A made-to-measure metal lid for a framed chimney chase, replacing a rusted pan that lets water into the wall.

Open →
Call (323) 524-5673